Back to GetFilings.com





UNITED STATES
SECURITIES AND EXCHANGE COMMISSION
Washington, D.C. 20549




FORM 10-K



(MARK ONE)

x  ANNUAL REPORT PURSUANT TO SECTION 13 OR 15(d) OF THE SECURITIES EXCHANGE ACT OF 1934

For the fiscal year ended December 31, 2001

OR

o  TRANSITION REPORT PURSUANT TO SECTION 13 OR 15(d) OF THE SECURITIES EXCHANGE ACT OF 1934

FOR THE TRANSITION PERIOD FROM ___________ TO _____________

Commission file number 000-30713

Intuitive Surgical, Inc.
(Exact name of Registrant as Specified in its Charter)

 
Delaware
77-0416458
  (State or Other Jurisdiction of Incorporation or Organization) 
(I.R.S. Employer Identification Number)

950 Kifer Road
Sunnyvale, California    94086

(Address of Principal Executive Offices including Zip Code)

(408) 523-2100
(Registrant's Telephone Number, Including Area Code)


Securities registered pursuant to Section 12(b) of the Act: None

Securities registered pursuant to Section 12(g) of the Act:
Common Stock, $.0001 Par Value

      Indicate by check mark whether the registrant (1) has filed all reports required to be filed by Section 13 or 15(d) of the Securities Exchange Act of 1934 during the preceding 12 months (or for such shorter period that the registrant was required to file such reports), and (2) has been subject to such filing requirements for the past 90 days. Yes x    o 

      Indicate by check mark if disclosure of delinquent filers pursuant to Item 405 of Regulation S-K is not contained herein, and will not be contained, to the best of Registrant's knowledge, in definitive proxy or information statements incorporated by reference in Part III of this Form 10-K, or any amendment to this Form 10-K.    o

      The aggregate market value of the voting stock held by non-affiliates of the registrant, based upon the closing price of Common Stock on March 15, 2002, as reported by Nasdaq, was approximately $279,861,580. Shares of voting stock held by each officer and director and by each person who owns 5% or more of the outstanding voting stock have been excluded in that such persons may be deemed to be affiliates. This assumption regarding affiliate status is not necessarily a conclusive determination for other purposes.

      The number of outstanding shares of the registrant's common stock on March 15, 2002 was 36,372,813.

DOCUMENTS INCORPORATED BY REFERENCE

      Part III -- Portions of the registrant's definitive Proxy Statement to be issued in conjunction with the Registrant's Annual Meeting of Stockholders to be held on May 23, 2002 are incorporated by reference into Part III.



Intuitive Surgical, Inc.

2001 ANNUAL REPORT ON FORM 10-K

INDEX

Part I.

 

Page

   Item 1.

Business

1

   Item 2.

Properties

15

   Item 3.

Legal Proceedings

16

   Item 4.

Submission of Matters to a Vote of Security Holders

17

Part II.

 

 

   Item 5.

Market for the Registrant's Common Equity and Related Stockholder Matters

17

   Item 6.

Selected Financial Data

17

   Item 7.

Management's Discussion and Analysis of Financial Condition and Results of Operations

21

   Item 7a.

Quantitative and Qualitative Disclosures About Market Risks

38

   Item 8.

Financial Statements and Supplementary Data

40

   Item 9.

Changes in and Disagreements with Accountants on Accounting and Financial Disclosures

40

Part III.

 

 

   Item 10.

Directors and Executive Officers of the Registrant

40

   Item 11.

Executive Compensation

42

   Item 12.

Security Ownership of Certain Beneficial Owners and Management

42

   Item 13.

Certain Relationships and Related Transactions

43

Part IV.

 

 

   Item 14.

Exhibits, Financial Statement Schedules and Reports on Form 8-K

43

Signatures

  

79

Exhibits Index

  

??








PART I

ITEM 1: BUSINESS

FORWARD LOOKING STATEMENTS

This Annual Report on Form 10-K contains forward-looking statements based on our current expectations about our company and our industry. You can identify these forward-looking statements when you see us using words such as "expect," "anticipate," "estimate" and other similar expressions. These forward-looking statements involve risks and uncertainties. Our actual results could differ materially from those anticipated in these forward-looking statements as a result of the factors described in the "Risk Factors" section of Management's Discussion and Analysis of Financial Condition and Results of Operations and elsewhere in this report. We undertake no obligation to publicly update any forward-looking statements for any reason, even if new information becomes available or other events occur in the future.

COMPANY BACKGROUND

In this report, "Intuitive Surgical," "we," "us," and "our" refer to Intuitive Surgical, Inc. Intuitive™®, da Vinci™, EndoWrist™, InSite™ and Navigator™ are trademarks of Intuitive Surgical, Inc.

We design and manufacture the da Vinci Surgical System, an advanced surgical system that we believe represents a new generation of surgery -- the third generation. We believe that this new generation of surgery, which we call Intuitive surgery, is a revolutionary advance similar in scope to the previous two generations of surgery -- open surgery and minimally invasive surgery, or MIS. Our da Vinci Surgical System consists of a surgeon's console, a patient-side cart, a high performance vision system and our proprietary instruments. By placing computer-enhanced technology between the surgeon and patient, we believe that our system enables surgeons to perform better surgery in a manner never before experienced. The da Vinci Surgical System seamlessly translates the surgeon's natural hand movements on instrument controls at a console into corresponding micro-movements of instruments positioned inside the patient through small puncture incisions, or ports. Our da Vinci Surgical System is the only commercially available technology that can provide the surgeon with the intuitive control, range of motion, fine tissue manipulation capability and 3-D visualization characteristic of open surgery, while simultaneously allowing the surgeon to work through the small ports of minimally invasive surgery.

In March 1997, surgeons using an early prototype of our technology successfully performed Intuitive surgery on humans. Beginning in May 1998, surgeons using our technology successfully performed what we believe were the world's first computer-enhanced closed chest heart surgeries, including mitral valve repair, dissection of an internal mammary artery and grafting of a coronary artery. In early 2000, surgeons using our technology successfully completed what we believe was the world's first beating heart bypass procedure using only small ports. In July 2000, we received marketing clearance from the U.S. Food and Drug Administration (FDA) for the da Vinci Surgical System to assist in the control of Intuitive Surgical endoscopic instruments including: rigid endoscopes, blunt and sharp endoscopic dissectors, scissors, scalpels, forceps/pickups, needle holders, endoscopic retractors, stabilizers, electrocautery, and accessories during laparoscopic surgical procedures such as cholecystectomy or Nissen fundoplication. We received clearance for a non-cardiac thoracoscopic surgery indication for the product in March 2001. Additionally, in May 2001 we received clearance for use of our products in laparoscopic prostatectomy procedures. As of December 31, 2001, we have sold 89 of our da Vinci Surgical Systems and surgeons using our technology have successfully completed several thousand surgery procedures of various types.

The first generation of surgery, open surgery, remains the predominant form of surgery and is still used in almost every area of the body. However, the large incisions required for open surgery create significant trauma to the patient, resulting in long hospitalization and recovery times, high hospitalization costs, as well as significant pain and suffering. Over the past several decades, the second generation of surgery, MIS surgery, has reduced trauma to the patient by allowing some surgeries to be performed through small ports rather than large incisions, resulting in shorter recovery times, fewer complications and reduced hospitalization costs. MIS surgery has been widely adopted for certain surgical procedures, but it has not been widely adopted for complex procedures. We believe surgeons have been slow to adopt MIS surgery for complex procedures because they generally find that fine tissue manipulations, such as dissecting and suturing, using these techniques are more difficult to learn and perform, and are less precise, than in open surgery.

Intuitive surgery overcomes many of the shortcomings of both open surgery and MIS surgery. Surgeons operate while seated comfortably at a console viewing a bright and sharp 3-D image of the surgical field. This immersive visualization results in surgeons no longer feeling disconnected from the surgical field and the instruments, as they do when using an endoscope in MIS surgery. While seated at the console, the surgeon manipulates instrument controls in a natural manner, just as he or she has been trained to do in open surgery. Our technology is designed to provide surgeons with a range of motion in the surgical field analogous to the motions of a human wrist, while filtering out the tremor inherent in every surgeon's hand. In designing our products, we have focused on making our technology as simple as possible to use. In our experience, based on over a thousand procedures, surgeons can learn to manipulate our instruments with only a short amount of training and can learn to perform Intuitive surgery with less training than is required for MIS surgery.

Our products are designed to make a broad range of open surgical and MIS procedures suitable for Intuitive surgery. The da Vinci Surgical System is designed to allow surgeons to perform better surgery while providing patients with the benefits of MIS surgery. We believe that these advantages will enable us to drive a fundamental change in surgery.

Third Generation Surgery: The Intuitive Surgical Solution

Our technology is designed to return to the surgeon the range of motion, fine tissue control and 3-D vision characteristic of open surgery while simultaneously allowing the surgeon to work through the ports used in MIS surgery. All this is accomplished in an intuitive manner, in the same way that the movements of a surgeon's hands in open surgery are entirely intuitive.

We believe that our technology overcomes many of the limitations of existing MIS surgery in the following ways:

We believe that these advantages give the patient the benefits of less traumatic MIS surgery while restoring to the surgeon the range of motion and fine tissue control possible with open surgery, along with further enhancements such as tremor reduction, motion scaling and superior visualization.

We believe that our technology has the potential to change surgical procedures in three basic ways:

INTUITIVE SURGICAL'S PRODUCTS

Our principal products include the da Vinci Surgical System and a variety of "smart disposable" EndoWrist instruments.

da Vinci Surgical System

Surgeon's Console. The da Vinci Surgical System allows the surgeon to operate while comfortably seated at an ergonomic console viewing a 3-D image of the surgical field. The surgeon's fingers grasp the instrument controls below the display with wrists naturally positioned relative to his or her eyes. Using hardware, software, algorithms, mechanics and optics, our technology is designed to seamlessly translate the surgeon's hand movements into precise and corresponding real-time microsurgical movements of the EndoWrist instruments inside the patient.

Patient-Side Cart. The patient-side cart, which can be easily moved next to the operating table, holds electromechanical arms that manipulate the instruments inside the patient. Three arms attached to the cart can be easily positioned as appropriate, and then locked into place. The first two arms, one representing the left hand and one the right hand of the surgeon, hold our EndoWrist instruments. The third arm positions the endoscope, allowing the surgeon to easily change, move, zoom and rotate his or her field of vision.

3-D Vision System. The vision system includes our InSite high resolution 3-D endoscope with two separate vision channels linked to two high resolution, progressively scanned color monitors. The vision system also incorporates our InSite image processing equipment comprised of high performance video cameras, specialized edge enhancement and noise reduction equipment. The resulting 3-D image has high resolution and contrast and no flicker or cross-fading, which occurs in single monitor systems, and minimizes eye fatigue. Our vision system allows the surgeon to move his or her head in the viewer without affecting image quality.

EndoWrist Instruments

We manufacture a variety of EndoWrist instruments, each of which incorporates a wrist joint for natural dexterity, with tips customized for various surgical procedures. These EndoWrist instruments are currently approximately seven millimeters in diameter. The instruments mount onto the electromechanical arms that represent the surgeon's left and right hands and provide the mechanical capability necessary for performing complex tissue manipulations through ports. At their tips, the various EndoWrist instruments include forceps, scissors, electrocautery, scalpels and other surgical tools that are readily familiar to the surgeon from open and MIS surgery. Generally, a variety of EndoWrist instruments are selected and used interchangeably during the surgery. Where instrument tips need to incorporate a disposable component, for example, scalpel blades, we sell disposable inserts. We plan to continue to add new types of EndoWrist instruments for additional types of surgical procedures.

The EndoWrist instruments are "smart disposables" because they are resterilizable and reusable for a defined number of procedures or hours of use. A custom computer chip inside each instrument performs several functions that help determine how the system and instruments work together. When an EndoWrist instrument is attached to an arm of the patient-side cart, the chip performs an "electronic handshake" that ensures the instrument was manufactured by us and recognizes the type and function of the instrument and number of past uses or hours. For example, the chip distinguishes between scissors and a scalpel and controls the unique functions of different instruments as appropriate. In addition, the chip will not allow the instrument to be used for more than the prescribed number of procedures or hours so that its performance meets specifications during each procedure. In addition, we can sell the instrument for a fixed number of uses or hours and effectively price our EndoWrist instruments on a per-procedure or per-hour basis.

USING THE DA VINCI SURGICAL SYSTEM

During a procedure, the patient-side cart is positioned next to the operating table with the electromechanical arms arranged to provide access to the initial ports selected by the surgeon. Metal tubes attached to the arms are inserted through the ports, and the EndoWrist instruments are introduced through the tubes into the patient's body. The surgeon then performs the procedure while sitting comfortably at the surgeon's console, manipulating the instrument controls and viewing the operation through our InSite vision system. When a surgeon needs to change an instrument, as is done many times during an operation, the instrument is withdrawn from the surgical field using the controls at the console, in similar fashion to the way a surgeon withdraws instruments from the patient in MIS surgery. A scrub nurse standing near the patient removes the unwanted instrument from the electromechanical arm and replaces it with the new instrument, in a process designed to be rapid enough not to disturb the natural flow of the procedure. As a result, the scrub nurse plays a role similar to that played in open and MIS surgery. At the conclusion of the operation, the metal tubes are removed from the patient's body and the small incisions are sutured or stapled.

OUR STRATEGY

Our goal is to establish Intuitive surgery as the standard for complex surgical procedures and many other procedures currently performed using either open or MIS surgery. We intend to accomplish this objective both by pioneering new types of endoscopic surgery and by making existing MIS procedures easier, safer and more cost effective. Over time, our strategy is to broaden the number of procedures performed using the da Vinci Surgical System and to educate surgeons and hospitals as to the benefits of Intuitive surgery. Key elements of this strategy include:

Focus on Key Institutions. Our marketing efforts are focused on large multi-specialty care hospitals where a majority of complex surgical procedures are performed. Following the initial placement at a given hospital, we intend to expand the number of physicians who use the da Vinci Surgical System and work with the hospitals and their surgeons to promote patient education as to the benefits of Intuitive surgery. We believe that these efforts will result in increased usage per system, leading to high volume sales of instruments and sales of additional systems at each hospital. In addition, we believe such efforts will benefit early-adopting hospitals by increasing their market share in the procedures and specialties that benefit from Intuitive surgery. We expect these efforts to increase demand for our products among competitive hospitals, surgeons and referring physicians.

Focus on Leading Surgeons to Drive Rapid and Broad Adoption. We will place significant emphasis on marketing the da Vinci Surgical System to leading surgeons who are considered to be the "thought leaders" in their institutions and fields. These surgeons typically perform complex surgical procedures that are currently not adaptable to MIS techniques. For example, cardiac procedures, of which over one million are currently performed annually worldwide, are among the most difficult to perform using MIS techniques. This strategy puts surgeons at the forefront of procedure development and provides them an opportunity to maintain a competitive edge in their specialty. We believe that early adoption of our products by surgical thought leaders will give many other surgeons the confidence that the da Vinci Surgical System can be used for all types of surgical procedures.

Develop Protocols for New Surgical Procedures. We intend to leverage our relationships with key institutions and surgical thought leaders to develop protocols for new surgical procedures. These protocols would include guidance on patient screening, port placement, interaction of the surgical team and advice on the sequence and selection of tools and maneuvers. We believe that establishing protocols for a given procedure will facilitate the broader adoption of Intuitive surgery for that procedure.

Maintain Market Leadership. We intend to maintain our leadership advantage by continuing to develop and enhance our technology and to communicate the benefits of our da Vinci Surgical System to surgeons, hospitals and patients. We will continue to improve our da Vinci Surgical System through software and hardware enhancements and by developing new surgical instruments. We will also continue to develop our surgical platform to facilitate and support future surgical innovations.

 

CLINICAL CONTRIBUTIONS

We believe our technology is capable of enhancing or enabling a wide variety of procedures in many surgical specialties. To date, surgeons using our da Vinci Surgical System have performed over a thousand surgery procedures of various types including general and vascular surgery, gynecologic and urologic surgery, and cardiovascular surgery. These applications, as well as potential applications for orthopedic surgery, are described below.

General and Vascular Surgery

Aortic Aneurysms. A common vascular procedure is the repair of aortic aneurysms, which are sacs formed by the dilation of the wall of the main artery in the body. Aneurysms are caused primarily by atherosclerosis, which is characterized by the deposition of fatty substances in large and medium-sized arteries, such as the arteries that lead to the heart and brain. Surgical treatment involves clamping the aorta and making long incisions at multiple sites to resect and replace the aneurysm with a synthetic graft. Once the aorta is clamped, time is of the essence, since procedures are typically done without heart/lung bypass machines. Thus, only a narrow window of time for completion is available. Currently, some aneurysms are treated by intravascular stent-grafts. These stent-grafts can be inserted through the main artery in the thigh, called the femoral artery, and do not require an incision. However, the necessity of traversing the femoral artery to gain access to the aorta limits the usage of this technique. We believe that the capability of our technology to deliver to the surgeon enhanced dexterity and the ability to suture grafts, alone or in conjunction with stent-grafts, will help convert this procedure from open surgery to Intuitive surgery.

Aorto-Femoral Bypass. The lower portion of the abdominal aorta is often a location of atherosclerosis. Atherosclerotic blockage of this portion of the aorta restricts blood flow to the lower body. To treat this condition using open surgery, a synthetic graft is attached above and below the blockage. This procedure currently requires open surgery because of the need to suture the grafts in place. We believe that with our technology, surgeons will be able to perform the required suturing of arteries, called an anastomosis, through ports and avoid the large incision currently required.

Cholecystectomy. Removal of the gallbladder, or cholecystectomy, is the most common procedure performed by general surgeons. The procedure is used to treat cholecystitis, which is an inflammation of the gall bladder. Although a minimally invasive approach, called a laparoscopic cholecystectomy, is now well accepted for routine cases, there is great variability in the level of skill required to accomplish the procedure. The skill level necessary to complete a laparoscopic cholecystectomy is dependent on the disease status the surgeon discovers after the abdomen is entered. For example, acute cholecystitis can result in inflammation and the abnormal union of tissues resulting from the formation of new fibrous tissue in the inflammatory process. As a result, very meticulous surgery to access gallbladder anatomy can be required. Similarly, during the operation, the surgeon may find a condition known as choledocolithiasis, or stones in the common bile duct. The surgeon may choose to incise or cut the common duct to extract stones that are caught between the liver and intestine. Exploration of the common bile duct is an extremely delicate procedure that requires micro-sutures to be placed in the common duct. Most surgeons will not do this procedure laparoscopically because of its difficulty. This usually results in a conversion to open technique or another surgical or delicate gastrointestinal endoscopic procedure to extract the stones. With our technology, we believe that the surgeon will have expanded capability to deal with complicated cholecystectomies and can avoid subjecting the patient to a second procedure.

Nissen Fundoplication. Nissen fundoplication is a general surgical procedure that is performed to correct esophageal reflux. Esophageal reflux disease is a digestive disorder that affects the muscle connecting the esophagus with the stomach. As an elective procedure, Nissen fundoplication is currently performed on only a small fraction of candidates who suffer from this condition because the open surgical procedure is quite invasive. An MIS alternative exists, but there are only a limited number of surgeons skilled in the procedure. We believe that our technology will significantly improve the ease of performing the Nissen procedure through ports. Specifically, our technology will address the two most difficult steps in this procedure, which are made more difficult by existing MIS techniques, esophageal dissection and suturing of the fundus of the stomach. If adoption of our technology becomes widespread for Nissen procedures, we believe that the number of surgeons able to perform a Nissen procedure using port-based techniques will increase. Further, we expect that the widespread availability of a port-based approach may significantly expand the number of surgeries performed.

Colon Resection. Removal of the colon or large bowel is a common general surgical procedure done for both benign and malignant disease. Colon resection is accomplished in a variety of ways by removing all or part of the colon. These procedures are complicated and involve resecting a portion of diseased tissue and then re-anastomosing the two ends of the colon to re-establish continuity of intestinal flow. When using existing MIS techniques, the challenge is to have enough manipulating capability to perform fine dissection of the colon and then to be able to sew or staple the ends of the bowel to accomplish the re-anastomosis. The MIS procedure is currently performed by only a small fraction of general surgeons. By making dissection significantly more precise, we believe that our products will allow port-based colon resection to be performed more widely.

Hernia Repair. An inguinal hernia is a condition in which tissue protrudes through the wall of the pelvis. It is caused by a defect or weakness in the lining covering the pelvic region. Repair of inguinal hernia is the second most common procedure done in general surgery. There are a variety of hernia procedures available that use both open and MIS techniques. However, the lack of precise dissection capability inhibits adoption of the MIS procedures. Specifically, the delicate dissection of some of the structures and the peritoneal sac, which often adheres to the pelvic anatomy, is very difficult for surgeons to accomplish using MIS techniques. We believe that our technology will encourage surgeons to convert hernia procedures to the port-based approach by removing the training barrier that limits its adoption.

Gynecologic Surgery

General Gynecology. Laparoscopy has been used for several decades in a large number of diagnostic infertility procedures. Although there are a variety of therapeutic infertility procedures that can currently be performed by some gynecologists using existing MIS techniques, these procedures are relatively difficult to perform using existing MIS tools because of the lack of tissue control, inability to perform fine dissection, and limited suturing capability. We believe that our technology will provide gynecologists with the ability to do sophisticated procedures such as tubal re-anastomosis and dissection of ovarian cysts, as well as common procedures such as surgical removal of an ovary or fallopian tube.

Hysterectomy. Removal of the uterus is one of the most commonly performed surgeries in gynecology and it can be done by using open or MIS techniques. Like colon resection, it demands a significant degree of tissue manipulation in the dissection and ligation, or tying, of blood vessels, ligaments and other pelvic structures. Further, laparoscopic techniques used in this procedure increase the risk of injury to the ureters, which are vital structures that provide the conduit for urine between the kidney and bladder. It is often difficult to ensure the identification and prevention of injury to the ureters and bladder with conventional MIS instruments because of the limited angles at which these instruments can be positioned. We believe that our products will increase the surgeon's dexterity in this procedure and, as a result, will have a significant impact on safety, operating time, and rate of adoption of port-based techniques in hysterectomy.

Bladder Neck Suspension. Bladder incontinence is a widespread condition affecting middle aged women, which can be treated surgically with a procedure known as bladder neck suspension. This procedure involves elevation of the bladder neck by suspension with sutures, surgically recreating the normal angle of the urethra and re-establishing bladder sphincter control. The procedure works well in open surgery and is the "gold standard" for correction of bladder incontinence. However, because of its long recovery time, most candidates are discouraged from undergoing the procedure using open surgical technique. Instead, they use adult diapers for their incontinence, which is an embarrassment and inconvenience. Bladder neck suspension can currently be done laparoscopically but is difficult to perform because of the need to suture at awkward angles using existing MIS instruments. We believe our technology may provide a better solution for suturing the bladder neck and would represent an advance in the ease of performing incontinence surgery.

Orthopedic Surgery

Arthroscopy. Many knee surgeries are accomplished by an MIS technique called arthroscopy. This technique is well accepted in the surgical community. However, many of the more sophisticated maneuvers in arthroscopy, such as suturing torn meniscal tissue, are very difficult with existing MIS instruments. The meniscus is a structure located in the knee joint that provides a surface and cushion upon which the bones of the knee joint can move. We believe that our technology and the capabilities of our EndoWrist instruments will increase the ease with which complex arthroscopic procedures such as advanced knee and shoulder arthroscopy can be performed.

Spinal Surgery. Disc removal and spinal fusion are common procedures performed in open spinal surgery. MIS techniques where surgeons approach the spine through the abdomen and use laparoscopic methods to expose the anterior portion of the spine and lumbar disc space are just emerging. This procedure requires both delicate and precise dissection and retraction of tissue, and would benefit greatly from the enhanced capabilities offered by the da Vinci Surgical System. We believe that our technology may make this procedure safer, easier, more precise, and allow more surgeons to perform it with confidence.

Cardiothoracic Surgery

Internal Mammary Artery Dissection. In a coronary artery bypass graft procedure used in cardiac surgery, a blocked coronary artery is bypassed with a graft. When available, an artery from the chest called the internal mammary artery is dissected from its natural position and grafted into place to perform the bypass. Because the internal mammary artery is located on the underside of the anterior surface of the chest, dissection of the vessel is challenging using existing surgical instruments through the three- to five-inch incision currently used in a coronary artery bypass graft procedure. Our products have multiple joints that emulate the surgeon's shoulders and elbows, allowing exact positioning of the instruments inside the patient's chest. In addition, the EndoWrist joints permit the surgeon to reach behind the tissues for easier dissection of the internal mammary artery. Thus, we believe that the internal mammary artery can be dissected with greater ease and precision using our technology.

Coronary Anastomosis. Coronary artery bypass graft surgery demands that the surgeon delicately dissect and precisely suture very small structures, which are less than two millimeters in diameter, under significant magnification. These procedures are difficult when performed in open surgery. They are even more difficult when performed using an endoscopic or limited incision approach, and extraordinarily difficult to perform when the heart is beating. As a result, this procedure is typically done as open surgery by stopping the heart and using a heart/lung bypass machine. Our technology is designed to allow surgeons to perform scaled instrument movements that can be even more precise than the movements used in open surgery, thus enabling precise suturing of single and multiple coronary vessels on a stopped or beating heart.

Mitral and Aortic Valve Repair/Replacement. Valve repair and replacement surgeries are challenging even when using open surgical techniques. Significant exposure of the surgical field is essential to the identification and precise manipulation of valves and other structures inside the heart, and is key to successful surgical outcomes with minimal complications. Motion scaling allows a surgeon using our da Vinci Surgical System to maneuver instruments inside the patient even more precisely than is possible in open surgery. Our system has already enabled heart valve repairs to be performed through small ports in a manner that could not have been accomplished with open surgery. Replacement of valves currently requires a small incision, even if the majority of the procedure is eventually performed through ports using our technology, because the replacement valve itself is too large to be inserted into the chest through a port. However, new valve designs that can be delivered through ports are being developed, and the small incisions necessary today to deliver a replacement valve to the heart may eventually not be required, allowing a surgeon using the da Vinci Surgical System to replace a valve entirely using ports.

Thoracoscopy. A number of procedures performed in the thorax, or chest cavity, can be accomplished by minimally invasive methods. These methods are generally referred to as thoracoscopic procedures. They include various types of lung resection, biopsy procedures, node dissections, nerve resections and esophageal surgery. Conventional thoracoscopic tools have all the limitations of conventional laparoscopic tools, such as "backward" movement and limited range of motion. The capability of our technology to operate dexterously in the often very small and restrictive space of the chest cavity is believed to offer significant clinical value in the performance of advanced thoracoscopic procedures.

MARKETING AND DISTRIBUTION

We market our products through a direct sales force in the United States and most of Europe. We have also entered into agreements with distributors in Italy and Japan. Our marketing and sales strategy in the United States and Europe involves the use of a combination of area sales managers, technical sales representatives and clinical training specialists. As of December 31, 2001, we had 70 employees in sales and marketing. We expect to significantly increase our sales and marketing force as we expand our business.

The role of our technical sales representatives is to educate physicians and surgeons on the advantages of Intuitive surgery and the clinical applications that our technology makes possible. We also train our technical sales representatives to educate hospital management on the potential benefits of early adoption of our technology and the potential for increased local market share that may result from Intuitive surgery. Once a hospital has installed a da Vinci Surgical System, our sales force will help introduce the technology to other surgical specialties within the hospital.

Clinical training specialists provide training and support to physicians and other hospital staff. We employ service technicians to install our da Vinci™ Surgical Systems and to provide non-clinical technical expertise, service and maintenance. We believe that this combination of technical sales representatives, clinical training specialists and service technicians provides an appropriate balance of professional selling skills while maintaining an appropriate level of technical expertise in the field.

Our da Vinci Surgical System has a lengthy sales and purchase order cycle because it is a major capital item and requires the approval of senior management at purchasing institutions. Particularly during the period in which our sales volume is low, this may contribute to fluctuations in our quarterly operating results.

TECHNOLOGY

Using key technologies, we have designed the da Vinci Surgical System to ensure intuitive control and fail-safe operation of the system. The system updates arm and instrument positions over 1,000 times per second, thereby ensuring real-time connectivity between the surgeon's hand movements and the movements of the instrument tips. A backup battery is included in the system that can power the system for more than 20 minutes in case of power loss or fluctuation. This 20-minute period is believed to be sufficient either to reestablish the power supply or for the hospital back-up power system to become effective.

Monitoring the operation of the system at all times is a network of approximately 20 micro-controllers that checks for proper system performance. System misuse or system fault can be detected and the system can be transitioned to a safe state in micro-seconds. The system also includes a sensor that detects the presence of the surgeon's head in the viewer. If the surgeon removes his or her head from the viewer, the system automatically disengages and locks the instruments in place to prevent their inadvertent movement.

The instrument controls at the surgeon's console have eight degrees of freedom of motion that allow the surgeon to move each hand through a workspace approximately one cubic foot in volume. These degrees of freedom allow the surgeon to orient his or her hands without limitation. The instrument controls are constructed with very low friction cables and gear transmissions to ensure smooth operation. Furthermore, critical components are constructed of magnesium and titanium to provide high mechanical stiffness and low inertia, ensuring a light and responsive feel to the surgeon.

The electromechanical arms of the patient-side cart are gravitationally counterbalanced to allow for smooth, easy and safe positioning of the instruments in the patient. The arms have seven degrees of freedom, allowing for control of position, orientation, translation and grip of the instrument, all inside the body. Redundant sensors are designed to ensure fail-safe operation of the instrument tips.

Unlike other 3-D systems, our InSite vision system relies on two entirely separate vision channels. Two eyepieces are linked by a precisely designed optical assembly to two high resolution, and high contrast medical grade monitors, which have been specially designed to have a high visual update rate that eliminates flicker and thus, reduces eye fatigue. Our stereo endoscope uses two separate high-resolution optical channels to improve image clarity. The stereo images pass through video processing electronics that provide specialized edge enhancement and noise reduction. A foot switch at the surgeon's console operates a focus controller on the endoscope. The endoscope self-regulates the temperature of its tip to eliminate fogging during procedures.

Our EndoWrist instruments use a wrist joint architecture driven by tiny but very high strength, flexible tungsten cables. Each tungsten cable is a "metal rope" constructed from over 200 fibers that are each less than one thousandth of an inch in diameter. These cables are similar in function to the tendons of a human wrist and are used to drive fluid motions of the wrist joint. The instruments each contain a custom memory chip that records and stores data each time the instrument is placed on the system. The chip contains encrypted security codes to protect against use of non-Intuitive Surgical instruments so that only our instruments will work with the da Vinci Surgical System. The chip identifies the type of tool being inserted so that different instrument types can be controlled uniquely by the system. The chip also records usage of the instrument and expires the instrument after its prescribed life.

INTELLECTUAL PROPERTY

Since our inception in late 1995, we have encountered and solved a number of technical hurdles. We have patented and continue to pursue patent and other intellectual property protection for the technology that we have developed to overcome such hurdles. In addition to developing our own patent portfolio, we have spent significant resources in acquiring exclusive license rights to necessary and desirable patents and other intellectual property from SRI International and IBM, who were early leaders in applying robotics to surgery. One of the strengths of our portfolio is that the licensed SRI International and IBM patents have original filing dates as early as January 1992 and June 1991, respectively. We have also exclusively licensed a patent application from MIT concerning robotic surgery. In April 2000, we exclusively licensed an extensive minimally invasive heart surgery patent portfolio from Heartport, Inc. in the field of robotic surgery. These patents cover many different forms of minimally invasive robotic surgery, including single- and multi-vessel coronary artery bypass grafts, heart valve repair and replacement and beating heart stabilization. In June 2001, we entered into a non-exclusive patent license with Olympus Optical Co., Ltd. of Japan for several robotic surgery patents. As of February 19, 2002, we hold exclusive field-of-use licenses for over 70 United States patents and approximately 40 foreign patents, and own outright 15 U.S. patents that expire no earlier than 2016. We also own or have licensed numerous pending United States and foreign patent applications, several of which were recently allowed. Our patents and patent applications relate to a number of important aspects of our technology, including our surgeon's console, electromechanical arms, vision system and our EndoWrist instruments. We intend to continue to file additional patent applications to seek protection for other proprietary aspects of our technology.

Our success will depend in part on our ability to obtain patent and copyright protection for our products and processes, to preserve our trade secrets, to operate without infringing or violating valid and enforceable proprietary rights of third parties, and to prevent others from infringing our proprietary rights. We intend to take action to protect our intellectual property rights when we believe doing so is necessary and appropriate. In addition, our strategy is to actively pursue patent protection in the United States and in foreign jurisdictions for technology that we believe is proprietary and that offers a potential competitive advantage, and to license appropriate technologies when necessary or desirable. We cannot be certain that we will be able to obtain adequate protection for our technology or licenses on acceptable terms. Furthermore, if any protection we obtain is reduced or eliminated, others could use our intellectual property without compensating us, resulting in harm to our business. In addition, the laws of certain foreign countries do not protect intellectual property rights to the same extent as do the laws of the United States. See "Item 7: Management's Discussion and Analysis of Financial Condition and Results of Operations -- Factors Affecting Operating Results." Others may assert that our products infringe their intellectual property rights, which may cause us to engage in costly disputes and, if we are not successful in defending ourselves, could also cause us to pay substantial damages and prohibit us from selling our products. In this regard, see "Item 3: Legal Proceedings" for a description of pending cases and interferences before the U.S. Patent and Trademark Office regarding our da Vinci Surgical System.

SRI International License Agreement

After receiving funding in 1990 from the U.S. Advanced Research Projects Agency, SRI International conducted research to develop a "telesurgery" system to allow surgeons to perform surgery on the battlefield from a remote location. SRI International developed the precise electromechanics, force-feedback systems, vision systems and surgical instruments needed to build and demonstrate a prototype system that could accurately reproduce a surgeon's hand motions with remote surgical instruments. In 1995, John G. Freund, M.D., one of our founders, acquired an option to license SRI International's telesurgery technology, which resulted in SRI International granting us a license.

Under the terms of our license agreement with SRI International, we have an exclusive, worldwide, royalty-free license to use the SRI International technology developed before September 12, 1997, including all patents and patent applications resulting from such work, in the field of manipulating tissues and medical devices in animal and human medicine, including surgery, laparoscopic surgery and microsurgery. We also have the right of first negotiation with respect to any SRI International technology developed in these areas before September 12, 1999 but after September 12, 1997.

Our license with SRI International will terminate upon the last expiration of the patents licensed from SRI International or December 20, 2012, whichever is later. Currently, the last patent expiration date is in 2016, although this could change. SRI International may terminate the license in the event of a material, uncured breach of our obligations. In the event SRI International terminates the license, we cannot assure you that the necessary licenses could be reacquired from SRI International on satisfactory terms, if at all.

IBM License Agreement

IBM conducted research on the application of computers and robotics to surgery during the late 1980s and early 1990s. IBM performed some of this work in conjunction with the Johns Hopkins Medical Center. Our license agreement with IBM covers a number of technologies related to the application of computers and robotics to surgery. Under the terms of this agreement, we have an exclusive, worldwide, royalty-free license to a number of IBM patents and patent applications in the field of surgery performed on animals and humans. We also have a non-exclusive license from IBM to practice in the areas of neurology, ophthalmology, orthopedics and biopsies. Under the license, we were obligated to make two payments to IBM, which were tied to revenue milestones. The final payment became payable in December 2001 and was paid in March 2002. The IBM license agreement will terminate upon the last expiration of the licensed patents. Currently, the last patent expiration date is in 2016, although this could change. IBM could have terminated the license had we failed to make the required payments. IBM may terminate the license in the event of a material, uncured breach of our obligations. In the event IBM terminates the license agreement, we cannot assure you that necessary licenses could be reacquired from IBM on satisfactory terms, if at all.

In March 2001, consistent with the terms of our license agreement with IBM, Intuitive and IBM jointly sued Computer Motion, Inc. in the U.S. District Court for the District of Delaware alleging infringement of U.S. Patent No. 6,201,984. Trial in this case is presently set for the third quarter of 2002. See "Item 3: Legal Proceedings" for a more detailed description of this litigation.

MIT License Agreement

After receiving funding from the U.S. Department of the Army, several researchers at MIT conducted research on various aspects of robotic surgical systems. As a result of that work, several patent applications were filed. Both MIT and the Army waived their rights to all but one of these applications, which the inventors ultimately assigned to us. MIT owns the other application. Under the terms of our license agreement with MIT, we have an exclusive, worldwide, royalty-free license to this patent application in the field of medical devices. The MIT license will terminate upon the last expiration of any patents issuing from the licensed patent application. MIT also has the right to terminate the MIT license in the event of a material, uncured breach of our obligations under the license. In the event MIT terminates the license, we cannot assure you that we would be able to reacquire a license from MIT on satisfactory terms, if at all.

Heartport, Inc. License Agreement

Since its inception in the early 1990s, Heartport, Inc. has developed an extensive patent portfolio covering systems and methods for performing many different aspects of minimally invasive heart surgery, including single- and multi-vessel coronary artery bypass grafts, heart valve repair and replacement, and beating heart stabilization. In April 2000, we acquired an exclusive, worldwide license in the field of robotic surgery to much of Heartport's portfolio, including many issued U.S. patents so far and many still-pending U.S. and foreign applications. The license is royalty-free unless we sell instruments for robotic surgery procedures that are not operated by the robotic surgery system, in which case we pay a small royalty.

Our license will terminate upon the last expiration of the patents licensed from Heartport. Currently, the last patent expiration date is in 2015, although this could change. Heartport may terminate the license in the event of a material, uncured breach of our obligations. In the event Heartport terminates the license, we cannot assure you that the necessary or desirable licenses could be reacquired from Heartport on satisfactory terms, if at all. Intuitive's exclusive license survives Johnson & Johnson's acquisition of Heartport.

In April 2001, Heartport became part of the Cardiovations Division of Ethicon, Inc., a Johnson & Johnson Company. Ethicon, Inc. therefore is now Intuitive's licensor under the Heartport license.

RESEARCH AND DEVELOPMENT

Substantially all of our research and development activity is performed internally. Our research and development team is divided into four groups: software engineering, systems analysis, electrical engineering and mechanical engineering. In addition, various members of the research and development team support the design and development of the manufacturing processes used in fabricating our products.

MANUFACTURING

Prior to February 2002, we leased a 13,000 square foot manufacturing facility in Mountain View, California. We used this facility and our manufacturing personnel to produce the systems and instruments that were sold and used in clinical trials through December 2001. The manufacture of our products is a complex operation involving a number of separate processes and components.

In February 2002, we moved our manufacturing facility to Sunnyvale, California. We now lease approximately 18,000 square feet of manufacturing space.

We purchase both custom and off-the-shelf components from a large number of certified suppliers and subject them to stringent quality specifications. We periodically conduct quality audits of suppliers and have established a supplier certification program. Some of the components necessary for the assembly of our products are currently provided to us by sole source suppliers or single source suppliers. We purchase components through purchase orders rather than long-term supply agreements and generally do not maintain large volumes of inventory. The disruption or termination of the supply of components could cause a significant increase in the costs of these components, which could affect our profitability. A disruption or termination in the supply of components could also result in our inability to meet demand for our products, which could harm our ability to generate revenues, lead to customer dissatisfaction and damage our reputation.

COMPETITION

We consider our primary competition to be existing open or MIS surgical techniques. Our success depends in part on convincing hospitals, surgeons and patients to convert procedures to Intuitive surgery from open or existing MIS surgery.

We also face competition from several companies that are developing new approaches and products for the minimally invasive surgery market, and, in particular, minimally invasive cardiac surgery. Many of these companies have an established presence in the field of MIS, including Boston Scientific Corporation, CardioThoracic Systems, Inc., a division of Guidant Corporation, C.R. Bard, Inc., Guidant Corporation, Heartport, Inc., Ethicon Endo-Surgery, Inc., a division of Johnson & Johnson, Medtronic, Inc., and United States Surgical Corporation, a division of Tyco International Ltd. If we are unable to compete successfully with these companies our revenues will suffer.

In addition, a limited number of companies are using robots and computers in surgery, including Brock Rogers Surgical, Inc., Computer Motion, Inc., Integrated Surgical Systems, Inc., Johns Hopkins University Engineering Research Consortium, Maquet AG, MicroDexterity Systems, Inc., Armstrong Healthcare Ltd., and Ross-Hime Designs, Inc. Our revenues may be reduced or eliminated if our competitors develop and market products that are more effective or less expensive than our products.

We believe that the primary competitive factors in the market we address are capability, safety, efficacy, ease of use, price, quality, reliability, and effective sales, support, training and service. The length of time required for products to be developed and to receive regulatory and reimbursement approval is also an important competitive factor.

GOVERNMENT REGULATION

United States

Our products and operations are subject to extensive and rigorous regulation by the FDA. The FDA regulates the research, testing, manufacturing, safety, labeling, storage, recordkeeping, promotion, distribution, and production of medical devices in the United States to ensure that medical products distributed domestically are safe and effective for their intended uses. In addition, the FDA regulates the export of medical devices manufactured in the United States to international markets.

Under the Federal Food, Drug, and Cosmetic Act (the "FFDCA"), medical devices are classified into one of three classes -- Class I, Class II or Class III -- depending on the degree of risk associated with each medical device and the extent of control needed to ensure safety and effectiveness. Our current products are Class II medical devices.

Class I devices are those for which safety and effectiveness can be assured by adherence to a set of guidelines, which include compliance with the applicable portions of the FDA's Quality System Regulation ("QSR"), facility registration and product listing, reporting of adverse medical events, and appropriate, truthful and non-misleading labeling, advertising, and promotional materials (the "General Controls"). Some Class I devices also require premarket clearance by the FDA through the 510(k) premarket notification process described below.

Class II devices are those which are subject to the General Controls and most require premarket demonstration of adherence to certain performance standards or other special controls, as specified by the FDA, and clearance by the FDA. Premarket review and clearance by the FDA for these devices is accomplished through the 510(k) premarket notification procedure. For most Class II devices, the manufacturer must submit to the FDA a premarket notification submission, demonstrating that the device is "substantially equivalent" to either:

(1) a device that was legally marketed prior to May 28, 1976, the date upon which the Medical Device Amendments of 1976 were enacted, or

(2) to another commercially available, similar device which was subsequently cleared through the 510(k) process.

If the FDA agrees that the device is substantially equivalent, it will grant clearance to commercially market the device. By regulation, the FDA is required to clear a 510(k) within 90 days of submission of the application. As a practical matter, clearance often takes longer. The FDA may require further information, including clinical data, to make a determination regarding substantial equivalence. If the FDA determines that the device, or its intended use, is not "substantially equivalent", the FDA will place the device, or the particular use of the device, into Class III, and the device sponsor must then fulfill much more rigorous premarketing requirements.

A Class III product is a product which has a new intended use or uses advanced technology that is not substantially equivalent to a use or technology with respect to a legally marketed device. The safety and effectiveness of Class III devices cannot be assured solely by the General Controls and the other requirements described above. These devices almost always require formal clinical studies to demonstrate safety and effectiveness.

Approval of a premarket approval application ("PMA") from the FDA is required before marketing of a Class III product can proceed. The PMA process is much more demanding than the 510(k) premarket notification process. A PMA application, which is intended to demonstrate that the device is safe and effective, must be supported by extensive data, including data from preclinical studies and human clinical trials and existing research material, and must contain a full description of the device and its components, a full description of the methods, facilities, and controls used for manufacturing, and proposed labeling. Once the FDA determines that an application is sufficiently complete to permit a substantive review, the FDA will accept the application for review. The FDA, by statute and by regulation, has 180 days to review a filed PMA application, although the review of an application frequently occurs over a significantly longer period of time, sometimes up to several years. In approving a PMA application or clearing a 510(k) application, the FDA may also require some form of post-market surveillance, whereby the manufacturer follows certain patient groups for a number of years and makes periodic reports to the FDA on the clinical status of those patients when necessary to protect the public health or to provide additional safety and effectiveness data for the device.

When FDA approval of a Class I, Class II or Class III device requires human clinical trials, and if the device presents a "significant risk" (as defined by the FDA) to human health, the device sponsor is required to file an investigational device exemption ("IDE") application with the FDA and obtain IDE approval prior to commencing the human clinical trial. If the device is considered a "non-significant" risk, IDE submission to the FDA is not required. Instead, only approval from the Institutional Review Board overseeing the clinical trial is required. Human clinical studies are generally required in connection with approval of Class III devices and to a much lesser extent for Class I and II devices.

In addition, our manufacturing processes are required to comply with the FDA's Good Manufacturing Practice (GMP) requirements contained in its Quality System Regulation (QSR). The QSR covers, among other things, the methods and documentation of the design, testing, production, processes, controls, quality assurance, labeling, packaging, and shipping of the Company's products. The QSR also requires maintenance of a device master record, device history record, and complaint files. The Company's domestic facility, records, and manufacturing processes are subject to periodic unscheduled inspections by the FDA.

In July 1997, we received 510(k) clearance from the FDA for the surgeon's console and patient cart to be used with only rigid endoscopes, blunt dissectors, retractors and stabilizer instruments. In November 1997, we withdrew a subsequent 510(k) submission covering additional instruments necessary for performing most surgical procedures, including scissors, scalpels, forceps/pickups, needle holders, clip appliers and electrocautery, after the FDA indicated that substantial clinical data would be required to support clearance.

In January 1999, we filed a 510(k) submission with clinical data, seeking clearance for the da Vinci Surgical System and EndoWrist instruments for laparoscopic surgical procedures. In May 1999, the FDA determined that our products were not eligible for 510(k) clearance but would instead be required to undergo the PMA approval process. On June 16, 1999, after review of the clinical data on the use of our products in laparoscopic surgical procedures, the FDA's General Surgery Advisory Panel recommended approval. In November 1999, we filed a PMA application to commercialize our products for laparoscopic surgery, which was accepted for review by the FDA in December 1999. In March 2000, the FDA inspected our Mountain View facility and determined, after conducting an extensive audit, that our facility and manufacturing practices were consistent with Good Manufacturing Processes. In June 2000, the FDA determined that the PMA approval process was inappropriate for the da Vinci Surgical System and re-classified the device as class II. The Premarket Approval Application submitted in November 1999 was closed and the original 510(k) application reactivated. In July 2000, we received a letter from the FDA informing us of their decision to clear the da Vinci Surgical System for use in laparoscopic surgery. The decision to reclassify the device to class II also means that future submissions for the da Vinci Surgical System may be reviewed under the premarket notification process unless changes to the intended use significantly change the safety and effectiveness of the device, in which case a PMA may be required.

Subsequent to Intuitive's July 2000 clearance of the da Vinci Surgical System, we have obtained additional 510(k) clearances from the FDA to include non-cardiac thoracoscopic surgical procedures (March 2001) and laparoscopic radical prostatectomy (May 2001). In November 2000, we submitted an investigational device exemption application to the FDA requesting permission to conduct a multi-center clinical evaluation of the da Vinci Surgical System for mitral valve repair. In December 2000, we received a letter from the FDA approving the trials for mitral valve repair. We have commenced this clinical trial and, if completed, we expect to submit a 510(k) to the FDA requesting permission to expand the intended use for the da Vinci Surgical System to include mitral valve repair. In July 2001, we submitted an investigational device exemption application to the FDA requesting permission to conduct a multi-center evaluation of the da Vinci Surgical System for atrial septal defect closure. In August 2001, we received a letter from the FDA approving trials for atrial septal defect closure. We have commenced this clinical trial and, if completed, we expect to submit a 510(k) to the FDA requesting permission to expand the intended use for the da Vinci Surgical System to include atrial septal defect closure. In January 2001, we submitted an investigational device exemption application to the FDA requesting permission to conduct a multi-center evaluation of the da Vinci Surgical System for totally endoscopic coronary artery bypass grafting. In April 2001, we received a letter from the FDA approving trials for totally endoscopic coronary artery bypass grafting. We have commenced this clinical trial and, if completed, we expect to submit a 510(k) to the FDA requesting permission to expand the intended use for the da Vinci Surgical System to include totally endoscopic coronary artery bypass grafting. While each of these trials is in progress, we cannot assure you that such trials will produce clinical data adequate to support a 510(k) application.

We are subject to inspection and market surveillance by the FDA to determine compliance with regulatory requirements. If the FDA finds that we have failed to comply, the agency can institute a wide variety of enforcement actions, ranging from a public warning letter to more severe sanctions. The FDA also has the authority to request repair, replacement or refund of the cost of any medical device manufactured or distributed by us. Our failure to comply with applicable requirements could lead to an enforcement action that may have an adverse effect on our financial condition and results of operations.

California Regulation

The state of California requires that we obtain a license to manufacture medical devices and subjects us to periodic inspection. Our facilities and manufacturing processes were inspected in February 1998. We passed the inspection and received our device manufacturing license from the Food and Drug Branch (FDB) of the California Department of Health Service in March 1998. In March 2002, our facilities and manufacturing processes in our Sunnyvale facility were re-inspected by the FDB. We passed this audit and are awaiting issuance of our device manufacturing license renewal.

Foreign Regulation

In order for us to market our products in other countries, we must obtain regulatory approvals and comply with extensive safety and quality regulations in other countries. These regulations, including the requirements for approvals or clearance and the time required for regulatory review, vary from country to country. Failure to obtain regulatory approval in any foreign country in which we plan to market our products may harm our ability to generate revenue and harm our business.

Commercialization of medical devices in Europe is regulated by the European Union. The European Union presently requires that all medical products bear the CE mark, an international symbol of adherence to quality assurance standards and demonstrated clinical effectiveness. Compliance with the Medical Device Directive, as certified by a recognized European Notified Body, permits the manufacturer to affix the CE mark on its products. In January 1999, following an audit of our quality system and Mountain View facility, we received permission from DGM, our Notified Body and agent of the Danish Government, to affix the CE mark to our da Vinci Surgical System and EndoWrist instruments for general surgical use, Class II-b. Additional CE approvals for use of our da Vinci Surgical System and EndoWrist instruments in cardiac surgery were received in September 1999 and February 2000, Class III.

If we modify existing products or develop new products in the future, we will need to apply for permission to affix the CE mark to such products. In addition, we will be subject to annual regulatory audits in order to maintain the CE mark permissions we have already obtained. We cannot be certain that we will be able to obtain permission to affix the CE mark for new or modified products or that we will continue to meet the quality and safety standards required to maintain the permissions we have already received. If we are unable to maintain permission to affix the CE mark to our products, we will no longer be able to sell our products in member countries of the European Union.

The Ministry of Health and Welfare regulates commercialization and reimbursement of medical devices in Japan. We have developed a clinical trial strategy for laparoscopic surgical use of the da Vinci Surgical System and EndoWrist instruments with our commercial partner in Japan. In May 2001 the proposed clinical trial strategy was approved by the Ministry of Health and Welfare. We commenced this clinical trial in June 2001 and, if completed, we expect to submit appropriate documentation to the Ministry of Health and Welfare requesting permission to commercialize the da Vinci Surgical System for conduct of laparoscopic surgical procedures in Japan. We are currently in the process of developing a cardiothoracic surgical clinical strategy with our commercial partner to facilitate conduct of an evaluation ultimately permitting expansion of the intended use for da Vinci Surgical System to include various cardiothoracic surgical procedures. However, we cannot assure you that we will succeed in procuring the required approvals to market our products in Japan or elsewhere, even if we develop a strategy and ultimately apply for these approvals.

THIRD-PARTY REIMBURSEMENT

In the United States and international markets where we intend to sell our products, the government and health insurance companies together are responsible for hospital and surgeon reimbursement for virtually all surgical procedures. Governments and insurance companies generally reimburse hospitals and physicians for surgery when the procedures are considered non- experimental and non-cosmetic. In the United States, reimbursement for medical procedures under the Medicare and Medicaid programs is administered by Centers for Medicare & Medicaid Services. Generally speaking, procedure codes are assigned by the American Medical Association using the copyrighted Current Procedural Terminology codes, which are in turn incorporated in the Medicare and Medicaid programs coding system. Applications for new procedure codes may be submitted to the American Medical Association.

Governments and insurance companies carefully review and increasingly challenge the prices charged for medical products and services. Reimbursement rates from private companies vary depending on the procedure performed, the third-party involved, the insurance plan involved, and other factors. Medicare reimburses hospitals a prospectively determined fixed amount for the costs associated with an in-patient hospitalization based on the patient's discharge diagnosis, and reimburses physicians a prospectively determined fixed amount based on the procedure performed. This fixed amount is paid regardless of the actual costs incurred by the hospital or physician in furnishing the care and is unrelated to the specific devices used in that procedure. Thus, any reimbursements that hospitals obtain for performing surgery with our products will generally have to cover any additional costs that hospitals incur in purchasing our products.

Domestic institutions will typically bill the services performed with our products to various third-party payors, such as Medicare, Medicaid and other government programs and private insurance plans. Because the da Vinci Surgical System has been cleared for commercial distribution in the United States by the FDA, Medicare reimbursement is available for use of the device in laparoscopic and thoracoscopic procedures and procedures conducted under an approved investigational device exemption application. We believe that the additional procedures we intend to target are generally already reimbursable by government agencies and insurance companies. If hospitals do not obtain sufficient reimbursement from third-party payors for procedures performed with our products, or if governmental and private payors' policies do not permit reimbursement for surgical procedures performed using our products, we may not be able to generate the revenues necessary to support our business. In such circumstances, we may have to apply to the American Medical Association for a unique Current Procedural Terminology code covering computer-enhanced surgery. If an application for a unique code is required, reimbursement for any use of our products may be unavailable until an appropriate code is granted. The application process, from filing until adoption of a new code, can take two or more years.

In countries outside the United States, reimbursement is obtained from various sources, including governmental authorities, private health insurance plans, and labor unions. In most foreign countries, private insurance systems may also offer payments for some therapies. Additionally, health maintenance organizations are emerging in certain European countries. To effectively conduct our business, we may need to seek international reimbursement approvals, and we do not know if these required approvals will be obtained in a timely manner or at all.

Any regulatory or legislative developments in domestic or foreign markets that eliminate or reduce reimbursement rates for procedures performed with our products could harm our ability to sell our products or cause downward pressure on the prices of our products, either of which would affect our ability to generate the revenues necessary to support our business.

EMPLOYEES

As of December 31, 2001, we had 241 employees, 50 of whom were engaged directly in research and development, 81 in manufacturing and service and 110 in marketing, sales, and administrative activities. None of our employees are covered by a collective bargaining agreement, and we consider our relationship with our employees to be good.

ITEM 2: PROPERTIES

We leased approximately 50,000 square feet in Mountain View, California. The lease expired in February 2002 and was not renewed.

Effective January 2002, we lease approximately 83,000 square feet in Sunnyvale, California. The facility is leased through April 2007, and we have an option to extend the lease for an additional five-year term.

ITEM 3: LEGAL PROCEEDINGS

On May 10, 2000, Computer Motion, Inc. filed a lawsuit in United States District Court for the Central District of California (Case No. CV00-4988 CBM) alleging that by making, using, selling or offering for sale our da Vinci Surgical System, we are infringing United States Patent Numbers 5,524,180, 5,762,458, 5,815,640, 5,855,583, 5,878,193, 5,907,664, and 6,001,108, in willful disregard of Computer Motion's patent rights. On June 1, 2000, Computer Motion amended its lawsuit to allege that we also infringe U.S. Patent Number 6,063,095. On October 30, 2000, Computer Motion filed a motion seeking to add U.S. Patent Number 6,102,850 to the litigation. Each of these nine patents concerns methods and devices for conducting various aspects of robotic surgery. Until February 2001, the litigation was proceeding in the early stages of discovery, with no trial date set. In February 2001, in response to our request, the District Court stayed -- put on hold -- all proceedings in the litigation because of the declaration by the U.S. Patent and Trademark Office ("PTO") of three "interference" proceedings between a single SRI patent application exclusively licensed to us and three of Computer Motion's patents (see next paragraph). In February 2002, the District Court extended the stay through a status conference presently scheduled for late March 2002 at which the parties will discuss with the Court the propriety of further extending the stay through decisions by the PTO in the interferences. The Computer Motion action seeks damages based upon the making, using, selling and offering for sale of our products and processes, and seeks to enjoin our continued activities relating to these products. This action subjects us to potential liability for damages, including treble damages, and could require us to cease making, using or selling the affected products, or to obtain a license in order to continue to manufacture, use or sell the affected products. While we continue to believe we have multiple meritorious defenses to this action, we cannot assure you that we ultimately will prevail on any issue in the litigation or that we will be able to successfully defend Computer Motion's charges, nor can we provide assurance that any license required would be made available on commercially acceptable terms, if at all. Failure to successfully defend against the Computer Motion action could harm our business, financial condition and operating results. Due to the inherent uncertainties of litigation, we cannot accurately predict the ultimate outcome of this matter at this time and, therefore, cannot estimate the range of possible loss.

On December 7 and 8, 2000, the PTO declared three interferences between a single SRI patent application exclusively licensed to Intuitive and three of Computer Motion's patents, Numbers 5,855,583, 5,878,193 and 5,907,664. An interference is a proceeding within the U.S. Patent Office to resolve questions regarding the patentability of inventions and who first invented subject matter claimed by two or more patents or patent applications. These three interferences resulted from requests for interference filed in May through July 1999. Because the SRI patent application licensed to Intuitive was filed in January 1992 and Computer Motion's three patents were filed no earlier than August 1992 and as late as February 1996, SRI/Intuitive is the "Senior Party" in each interference. As "Junior Party," Computer Motion bears the burden of proving that it is entitled to keep its patents. In papers filed with the PTO in March 2001, Computer Motion admitted that SRI/Intuitive filed for its involved patent application before Computer Motion thought of its inventions. We therefore anticipate that a second "priority" phase of each interference to determine which party invented the technology first will be unnecessary. During the first half of 2001, the parties filed over 20 motions in the three interferences. On October 10, 2001, the PTO held a hearing on all motions filed in all three interferences. Decisions regarding all of the motions are presently expected by the end of April 2002.

In September 2000, we filed a Notice of Opposition in the European Patent Office ("EPO") challenging European Patent No. 653,922, which was issued to Computer Motion in 1999 and is related to several of the patents now involved in the California litigation and the interference proceedings. An Opposition proceeding allows the EPO to determine whether the challenged patent should be revoked in its entirety, should be amended, or should remain unaltered. In its Notice of Opposition, Intuitive cited numerous prior art references not cited to the EPO during the '922 patent's original prosecution. A hearing is expected sometime in 2002.

On March 30, 2001, Intuitive and International Business Machines Corporation ("IBM") jointly filed suit against Computer Motion, Inc. in the U.S. District Court for the District of Delaware. The complaint alleges that by continuing to make, use, sell, and offer for sale its AESOP and ZEUS voice-controlled products, Computer Motion willfully infringes U.S. Patent No. 6,201,984. The '984 patent which concerns various aspects of voice control of surgical instruments issued to IBM in early March 2001 and is exclusively licensed to us. The '984 patent predates by several years Computer Motion's development of voice-controlled surgical robots. Because Computer Motion's voice-controlled HERMES product interfaces with the AESOP and ZEUS products, HERMES is also implicated in the patent infringement complaint. Trial is presently set for the third quarter of 2002. The Court so far has denied Computer Motion's request to add its own U.S. Patent No. 6,244,809 to this Delaware litigation and has refused to entertain Computer Motion's allegations that we infringe the '809 patent by making, using, selling and offering for sale our da Vinci Surgical System. The Delaware Court has also refused Computer Motion's request to transfer the litigation to California.

On September 1, 2000, Brookhill-Wilk 1, LLC ("Wilk") filed a lawsuit in the United States District Court for the Southern District of New York (Case No. 00 Civ. 6599 (NRB) alleging that by making, using, selling or offering for sale our da Vinci Surgical System, we are infringing U.S. Patent Nos. 5,217,003 and 5,368,015 in willful disregard of Wilk's patent rights. These patents concern methods and devices for "remote" surgery. In March 2001, Wilk withdrew its assertion of infringement of the '015 patent against Intuitive, leaving only the '003 patent at issue in the suit. On November 8, 2001, the District Court granted summary judgment of noninfringement of the '003 patent in our favor and dismissed Wilk's complaint in its entirety. Wilk has since filed a notice with the U.S. Court of Appeals for the Federal Circuit to appeal the summary judgment ruling. Briefing on the appeal should conclude in mid-2002, with a hearing date possible towards the end of 2002 or in early 2003. We believe the appellate court will uphold the summary judgment of noninfringement. If we lose Wilk's suit against us, it will hurt our competitive position, may be costly to us and may prevent us from selling our products. In addition, if we lose the patent suit, we may need to obtain from Wilk a license to this technology if we are to continue to market our products that have been found to infringe Wilk's patents. This license could be expensive, which could seriously harm our business. We believe that we have multiple meritorious defenses in this action. However, litigation is unpredictable and we may not prevail with any of these defenses. If Wilk is successful in its suit against us and is unwilling to grant us a license, we may be required to stop selling our products that are found to infringe Wilk's patents unless we can redesign them so they do not infringe Wilk's patents, which we may be unable to do. In addition, if we lose the patent suit, we could be required to pay Wilk damages, including treble damages, which could be substantial and harm our financial position.

ITEM 4: SUBMISSION OF MATTERS TO A VOTE OF SECURITY HOLDERS

None.

PART II

ITEM 5: MARKET FOR REGISTRANT'S COMMON EQUITY AND RELATED STOCKHOLDER MATTERS

PRICE RANGE OF COMMON STOCK

Our common stock has been traded on The Nasdaq Stock Market under the symbol "ISRG" since June 13, 2000. The following table sets forth the high and low sales prices of our Common Stock for the periods indicated and are as reported by Nasdaq.

QUARTER

HIGH

LOW

Year Ended December 31, 2001:
First Quarter
Second Quarter
Third Quarter
Fourth Quarter

 
$ 9.1250
14.7800
14.1500
10.7500

 
$ 4.8750
3.0000
4.9900
6.0100

Year Ended December 31, 2000:
Second Quarter
Third Quarter
Fourth Quarter

 
$ 11.1250
19.0625
15.0625

 
$ 7.8750
9.4375
5.3750

As of December 31, 2001, there were approximately 288 stockholders of record of our common stock, although we believe that there are a significantly larger number of beneficial owners of our common stock.

DIVIDEND POLICY

We have never declared or paid any cash dividends. We currently expect to retain earnings for use in the operation and expansion of our business, and therefore do not anticipate paying any cash dividends for at least the next three years.

ITEM 6: SELECTED CONSOLIDATED FINANCIAL DATA

The following selected consolidated financial data should be read in conjunction with the Consolidated Financial Statements and the accompanying Notes to such consolidated statements and "Management's Discussion and Analysis of Financial Condition and Results of Operations" included elsewhere in this Form 10-K. The selected data in this section is not intended to replace the consolidated financial statements.


                                                           Year Ended December 31,
                                            -----------------------------------------------------
                                              2001       2000       1999       1998       1997
                                            ---------  ---------  ---------  ---------  ---------
                                                      (In Thousands, Except Per Share Data)
CONSOLIDATED STATEMENTS OF
OPERATIONS DATA:
Sales..................................... $  51,673  $  26,624  $  10,192  $     --   $     --
Cost of sales.............................    28,218     18,031      9,273        --         --
                                            ---------  ---------  ---------  ---------  ---------
Gross profit..............................    23,455      8,593        919        --         --
                                            ---------  ---------  ---------  ---------  ---------
Operating costs and expenses:
  Research and development................    13,851     11,734     11,130     23,208     14,282
  Selling, general and administrative.....    29,987     19,136      9,338      7,565      4,434
  Technology license......................       --         --         --         --       6,000
                                            ---------  ---------  ---------  ---------  ---------
          Total operating expenses........    43,838     30,870     20,468     30,773     24,716
                                            ---------  ---------  ---------  ---------  ---------
Loss from operations......................   (20,383)   (22,277)   (19,549)   (30,773)   (24,716)
Interest income (expense), net............     3,683      3,754      1,134      1,330      1,114
                                            ---------  ---------  ---------  ---------  ---------
Net loss.................................. $ (16,700) $ (18,523) $ (18,415) $ (29,443) $ (23,602)
                                            =========  =========  =========  =========  =========

Basic and diluted net loss per share...... $   (0.47) $   (0.78) $   (3.81) $   (8.14) $  (11.24)
                                            =========  =========  =========  =========  =========
Shares used in computing basic and
  diluted net loss per share..............    35,815     23,796      4,837      3,619      2,100
                                            =========  =========  =========  =========  =========


                                                                  December 31,
                                            -----------------------------------------------------
                                              2001       2000       1999       1998       1997
                                            ---------  ---------  ---------  ---------  ---------
                                                                 (In Thousands)
CONSOLIDATED BALANCE SHEET DATA:
Cash, cash equivalents and short-term
  investments............................. $  66,661  $  89,441  $  26,260  $  23,220  $  32,674
Working capital...........................    67,922     83,836     22,023     19,817     25,424
Total assets..............................   100,361    112,421     34,455     28,167     35,674
Notes payable, less current portion.......       771      1,861      2,521      2,438        897
Deferred compensation.....................      (886)    (2,483)      (943)    (1,128)    (1,831)
Accumulated deficit.......................  (110,370)   (93,670)   (75,147)   (56,732)   (27,289)
Total stockholders' equity................    78,293     90,730     22,211     20,596     27,331


The consolidated statements of operations data for the years ended December 31, 2001, 2000, and 1999, and the consolidated balance sheet data at December 31, 2001 and 2000 are derived from our consolidated financial statements which have been audited by Ernst & Young LLP and included elsewhere in this Form 10-K. The consolidated statement of operations data for the years ended December 31, 1998 and 1997 and the consolidated balance sheet data at December 31, 1999, 1998, and 1997 are derived from our audited consolidated financial statements that are not included in this Form 10-K. Historical results are not indicative of the results to be expected in the future.

 

ITEM 7: MANAGEMENT'S DISCUSSION AND ANALYSIS OF FINANCIAL CONDITION AND RESULTS OF OPERATIONS

The following discussion and analysis should be read in conjunction with "Selected Consolidated Financial Data" and our consolidated financial statements and the related notes.

Except for historical information, the discussion in this report contains forward-looking statements that involve risks and uncertainties, such as statements of our plans, objectives, expectations and intentions. The cautionary statements made in this report should be read as applying to all related forward-looking statements wherever they appear in this report. Our actual results could differ materially from those discussed here. Factors that could cause or contribute to these differences include those discussed in "-- Factors Affecting Operating Results" below as well as those discussed elsewhere.

OVERVIEW

We design, manufacture, and market the da Vinci Surgical System, an advanced surgical system that we believe represents a new generation of surgery. The da Vinci Surgical System consists of a surgeon's console, a patient-side cart, a high performance vision system and proprietary instruments. The da Vinci Surgical System seamlessly translates the surgeon's natural hand movements on instrument controls at a console into corresponding micro-movements of instruments positioned inside the patient through small puncture incisions, or ports. We believe that the da Vinci Surgical System is the only commercially available technology that can provide the surgeon with the intuitive control, range of motion, fine tissue manipulation capability and 3-D visualization characteristic of open surgery, while simultaneously allowing the surgeon to work through the small ports of minimally invasive surgery or MIS. By placing computer-enhanced technology between the surgeon and the patient, we believe that the da Vinci Surgical System enables surgeons to perform better surgery while giving patients the benefits of MIS surgery, including decreased trauma and postoperative pain, reduced surgical complications, shorter hospital stays and lower total treatment costs.

In 1999, we obtained permission from the European Union to affix the CE Mark to the da Vinci Surgical System and EndoWrist instruments for general surgical and cardiac surgical use. Based on this approval, we recognized revenue for the first time in the second quarter of 1999 for the sale of our products. In July 2000, we received clearance from the U.S. Food and Drug Administration, the FDA, to begin commercialization of our da Vinci Surgical System in the United States for use in laparoscopic surgical procedures. In March 2001, we received clearance from the FDA for use of our da Vinci Surgical System in non-cardiac thoracoscopic surgical procedures. In May 2001, we received market clearance from the FDA to promote use of the da Vinci Surgical System for performance of laparoscopic radical prostatectomy procedures.

To date, the majority of our revenues have come from the sales of the da Vinci Surgical System, which are high revenue dollar items. A smaller percentage of revenues have come from sales of EndoWrist instruments and accessories, which are lower revenue dollar items. A small percentage of revenue also comes from ongoing service of installed da Vinci Surgical Systems. Although we expect the majority of our revenues to continue to come from the sale of da Vinci Surgical Systems over the next few years, the percentage of revenue from our EndoWrist instruments and service should continue to increase. Due to the high dollar revenue per system sold, small variations in system unit sales may cause revenue to vary significantly from quarter to quarter. During the useful life of each installed da Vinci Surgical System, we expect to generate recurring revenue through sales of the EndoWrist instruments and accessories and ongoing service.

 

RESULTS OF OPERATIONS

Sales. Sales for the fiscal year ended December 31, 2001 were $51.7 million, up 94% from $26.6 million for the fiscal year ended December 31, 2000. The sales increase was primarily due to an increase in the number of da Vinci Surgical Systems sold to 49 in 2001 from 28 in 2000. Fiscal year 2000 sales were up $16.4 million, or 161%, from $10.2 million for the fiscal year ended December 31, 1999. The sales increase was primarily due to an increase in the number of da Vinci Surgical Systems sold to 28 in 2000 from 12 in 1999.

Gross Profit. Gross profit for the fiscal year ended December 31, 2001 was $23.5 million, or 45% of sales, compared to $8.6 million, or 32% of sales in the previous fiscal year. The improvement in gross profit compared to the prior year resulted from sales growth and increased manufacturing efficiencies. Fiscal year 2001 and 2000 gross profit were both negatively impacted by a $1.0 million non-routine royalty charge that became due to IBM when Intuitive Surgical exceeded $50.0 million in annual revenue in 2001 and $25.0 million in 2000. Excluding the impact of this charge, fiscal year 2001 gross profit would have been $24.5 million, or 47% of sales, and fiscal year 2000 gross profit would have been $9.6 million or 36% of sales. The 2001 royalty payment represents the final royalty obligation under our agreement with IBM.

Fiscal year 1999 gross profit was $919,000, or 9%. Fiscal year 1999 was the first year in which revenue was recognized.

Research and Development Expenses. Fiscal year 2001 research and development costs were $13.9 million, up 18% from $11.7 million in fiscal year 2000. The increase was due to headcount increases and higher prototype material costs. Fiscal year 2000 research and development expenses of $11.7 million were up 5% from $11.1 million in 1999. The increase was primarily due to headcount increases, offset by a decrease caused by classifying manufacturing costs as cost of sales instead of research and development beginning in the second quarter of 1999, as sales were recorded for the first time, and lower fiscal year 2000 prototype materials costs.

Research and development expenses include costs associated with the design, development, testing and enhancement of our products. These enhancements represent significant improvements to our products. Research and development expenses also include expenditures for clinical trials and purchases of laboratory supplies. Research and development costs are expensed as incurred. We expect to continue to make substantial investments in research and development and anticipate that research and development expenses will continue to increase in the future.

Selling, General and Administrative Expenses. Selling, general and administrative expenses for fiscal year 2001 were $30.0 million, up 57% from $19.1 million for fiscal year 2000. The year-over-year increase was due in large part to increases in headcount in the field service and sales functions to support increased revenue and a larger installed base of da Vinci Surgical Systems. Selling, general and administrative expenses for fiscal year 2000 were $9.8 million higher than fiscal 1999 expenses of $9.3 million. This increase was primarily due to headcount increases resulting from growing sales and marketing activities as the da Vinci Surgical System received US FDA clearance in fiscal year 2000.

Selling, general and administrative expenses include personnel costs for sales, marketing and administrative personnel, tradeshow expenses, legal expenses, regulatory fees and general corporate expenses. Selling, general and administrative expenses are expected to increase in the future to support our expanding business.

Deferred Compensation. We record deferred compensation as the difference between the exercise price of options granted and the fair value of our common stock at the time of grant for financial reporting purposes. Deferred compensation is amortized to research and development expenses and selling, general and administrative expenses. For the years ended December 31, 2001, 2000 and 1999, the Company recorded amortization of deferred stock compensation of $1.6 million, $2.5 million and $865,000, respectively. For fiscal years 2001, 2000 and 1999 non-cash deferred compensation expense included in research and development expenses was $1.0 million, $1.9 million and $653,000, respectively. For fiscal years 2001, 2000 and 1999 non-cash deferred compensation expense included in selling, general and administrative expenses was $560,000, $684,000 and $212,000, respectively. Deferred compensation recorded through December 31, 2001 was $8.9 million with accumulated amortization of $8.0 million. The remaining $886,000 will be amortized over the remaining vesting periods of the options, generally four years from the date of grant, using a graded-vesting method. Future amortization of deferred compensation at December 31, 2001 is as follows: 2002 -- $662,000; and 2003 -- $227,000. The amount of deferred compensation expense to be recorded in future periods may decrease if unvested options for which deferred compensation has been recorded are subsequently canceled.

Interest Income. Interest income decreased 8% to $3.9 million for the fiscal year ended December 31, 2001 from $4.3 million in fiscal 2000. The decrease resulted primarily from lower interest rates earned on cash and short-term investment balances in 2001. Fiscal year 2000 interest income was $2.8 higher than fiscal year 1999 resulting from higher cash and short-term investment balances, driven by the exercise of warrants to purchase preferred stock in March 2000, yielding approximately $34.8 million in net proceeds, and our initial public offering in June and July 2000, which raised net proceeds of approximately $46.8 million.

LIQUIDITY AND CAPITAL RESOURCES

Prior to our initial public offering, operations were financed primarily through sales of our preferred stock, yielding net proceeds of approximately $127.3 million, and equipment financing arrangements yielding approximately $7.5 million. In June and July 2000, we completed the initial public offering of 5,750,000 shares of our common stock and realized net proceeds of approximately $46.8 million.

As of December 31, 2001, we had cash, cash equivalents and short-term investments of $66.7 million, compared to $89.4 million at December 31, 2000 and $26.3 million at December 31, 1999. Working capital at December 31, 2001 was $67.9 million, compared to $83.8 million at December 31, 2000 and $22.0 million at December 31, 1999. The fiscal year 2001 decrease in cash and investments and working capital was primarily attributable to cash used to fund operating losses and to acquire fixed assets. The fiscal year 2000 increase in cash and investments and working capital was primarily due to proceeds from issuance of preferred stock of $34.8 million and initial public offering proceeds of $46.8 million, offset by cash used to fund operating losses.

Net cash used in operating activities was $18.6 million for the fiscal year ended December 31, 2001, compared to $12.8 million for the fiscal year ended December 31, 2000 and $15.9 for the fiscal year ended December 31, 1999. The increase in cash used in operations during 2001 compared to 2000 reflects higher working capital requirements in 2001, primarily caused by the growth in the Company's receivable balances. The accounts payable and other accrued liabilities remained relatively flat. The decrease in cash used in operations in 2000 compared to 1999 resulted primarily from a lower net loss for 2000 after adjusting for non-cash charges for depreciation and deferred compensation.

Net cash provided by investing activities was $11.2 million for the fiscal year ended December 31, 2001, compared to net cash used in investing activities of $50.8 million in 2000 and $10.3 million used in 1999. Fiscal year 2001 cash provided resulted from the net conversion of short-term investments into cash to support operations. The increase in cash used in investing activities between 2000 and 1999 is related to the purchase of short- term investments with the net proceeds from our initial public offering in June and July 2000 and from the exercise of warrants to purchase preferred stock in March 2000.

Net cash provided by financing activities was $771,000 for the fiscal year ended December 31, 2001, compared to $82.2 million for 2000 and $20.2 million for 1999. Fiscal year 2001 cash provided by financing resulted from proceeds from the issuance of common stock (resulting mainly from the employee stock purchase plan and the exercise of stock options) for $2.3 million, offset by the net repayment of long-term equipment financing debt of $1.5 million. Cash provided by investing activities in fiscal 2000 related primarily to our initial public offering in June and July 2000, yielding net proceeds of $46.8 million. Proceeds from the issuance of preferred stock were $34.8 million and $19.3 million in 2000 and 1999, respectively.

Our capital requirements depend on numerous factors, including market acceptance of our products, the resources we devote to developing and supporting our products and other factors. We expect to devote substantial capital resources to continue our research and development efforts, to expand our customer support and product development activities and for other general corporate activities. We believe that our current cash and short-term investment balances, together with revenue to be derived from the sale of our products, will be sufficient to meet our liquidity requirements at least through 2003. During or after this period, if cash generated by operations is insufficient to satisfy our liquidity requirements, we may need to sell additional equity or debt securities or obtain additional credit arrangements. Additional financing may not be available on terms acceptable to us or at all. The sale of additional equity or convertible debt securities may result in additional dilution to our stockholders.

Contractual Obligations and Commercial Commitments. The following table summarizes all significant contractual payment obligations by payment due date:

Payments by Period ($ Millions)

Contractual Obligation

Total

Under 1 Year

1-3 Years

Over 4Years

Long-term Debt

$2.4

$1.6

$0.8

-

Non-Routine Royalty

$1.0

$1.0

-

-

Building Lease

$12.4

$1.3

$7.3

$3.8

Total

$15.8

$3.9

$8.1

$3.8

CRITICAL ACCOUNTING POLICIES

The Company believes the following represent its critical accounting policies:

Revenue Recognition. In certain cases, revenue from direct system sales is generated from multiple element arrangements which require judgement in the areas of delivery, customer acceptance, installation and collectibility. Revenue is recognized as specific elements indicated in sales contracts are executed. If an element is essential to the functionality of the system, revenue is deferred until that essential element is delivered. The fair value of each undelivered element that is not essential to the functionality of the system is deferred until performance occurs. The fair value of an undelivered element is based upon an estimate made by management. Amounts billed in excess of revenue recognized is recorded as deferred revenue on the balance sheet.

Warranties. We provide for the estimated costs of product warranties at the time revenue is recognized. The Company's estimate of costs to service its warranty obligations is based upon historical experience and expectation of future conditions. Should warranty claim activity and the costs associated with servicing those claims differ from the Company's estimates, revisions to the estimated warranty liability may be required.

Allowance for Doubtful Accounts. The allowance for doubtful accounts is based upon management estimates. Factors underlying these estimates include analysis of days outstanding, customer payment history and management judgement. The allowance is adjusted regularly to reflect current data and activity.

Inventory Reserves. We write our inventory down for estimated obsolescence or unmarketable inventory equal to the difference between the cost of inventory and the estimated market value based upon assumptions about future demand and market conditions. If actual future demand or market conditions are less favorable than those projected by management, additional inventory write-downs may be required.

Intangible Assets. We have intangible assets on our balance sheet related to the acquisition of patents. The valuation and classification of these assets and the assignment of useful amortization lives involves judgments and the use of estimates. The testing of these intangibles for impairment under established accounting guidelines is required on an ongoing basis. Changes in business conditions could potentially require future adjustments to asset valuations.

Contingencies. We are subject to proceedings, lawsuits and other claims related to our products, patents and other matters. We are required to assess the likelihood of any adverse judgments or outcomes to these matters as well as potential ranges of probable losses. A determination of the amount of reserves required, if any, for these contingencies is made after careful analysis of each individual issue. The required reserves may change in the future due to new developments in each matter or changes in approach such as a change in settlement strategy in dealing with these matters.

A complete description of all significant accounting policies is included in Note 1 in the Notes to the consolidated financial statements, in Item 14 of this Annual Report on Form 10-K.

RECENT ACCOUNTING PRONOUNCEMENTS

In June 1998, the Financial Accounting Standards Board (FASB) issued Statement of Financial Accounting Standards (SFAS) No. 133, "Accounting for Derivative Instruments and Hedging Activities" ("SFAS 133"). We adopted SFAS 133 effective January 1, 2001. This statement establishes accounting and reporting standards requiring that every derivative instrument, including certain derivative instruments embedded in other contracts, be recorded in the balance sheet as either an asset or liability measured at its fair value. The statement also requires that changes in the derivative's fair value be recognized in earnings unless specific hedge accounting criteria are met. The adoption of SFAS 133, as amended, has not had a significant impact on our financial position or results of operations.

In July 2001, the FASB issued SFAS No. 141 "Business Combinations" and SFAS No. 142 "Goodwill and Other Intangible Assets," effective for fiscal years beginning after December 15, 2001. SFAS No. 141 requires that the purchase method of accounting be used for all business combinations initiated after June 30, 2001, and that the use of the pooling-of-interest method is no longer allowed. Under SFAS No. 142 goodwill and intangible assets deemed to have indefinite lives will no longer be amortized but will be subject to an annual impairment test in accordance with the new standards. Other intangible assets will continue to be amortized over their respective useful lives. The Company will adopt SFAS No. 141 and SFAS No. 142 as of January 1, 2002. The Company does not currently believe that the adoption of SFAS No. 141 and SFAS No. 142 will have a significant impact on its financial position or results of operations.

In August 2001, the FASB issued SFAS No. 144 "Accounting for the Impairment or Disposal of Long-Lived Assets", effective for fiscal years beginning after December 15, 2001. SFAS No. 144 addresses financial accounting and reporting for impairment or disposal of long-lived assets and supersedes SFAS 121. The Company will adopt SFAS No. 144 as of January 1, 2002. The Company does not currently believe that the adoption of SFAS No. 144 will have a significant impact on its financial position or results of operations.

FACTORS AFFECTING OPERATING RESULTS

OUR FUTURE OPERATING RESULTS MAY BE BELOW SECURITIES ANALYSTS' OR INVESTORS' EXPECTATIONS, WHICH COULD CAUSE OUR STOCK PRICE TO DECLINE.

Because of our limited operating history, we have limited insight into trends that may emerge in our market and affect our business. The revenue and income potential of our market are unproven, and we may be unable to generate significant commercial revenues. In addition, our costs may be higher than we, securities analysts or investors expect. If we fail to generate sufficient revenues or our costs are higher than we expect, our results of operations will suffer, which in turn could cause our stock price to decline. Further, future revenue from sales of our products, if any, will be difficult to forecast because the market for new surgical technologies is still evolving. Our results of operations will depend upon numerous factors, including:

Our operating results in any particular period will not be a reliable indication of our future performance. It is likely that in some future quarters, our operating results will be below the expectations of securities analysts or investors. If this occurs, the price of our common stock, and the value of your investment, will likely decline.

WE HAVE A LARGE ACCUMULATED DEFICIT, WE EXPECT FUTURE LOSSES, AND WE MAY NOT ACHIEVE OR MAINTAIN PROFITABILITY.

We have incurred substantial losses since inception and we expect to incur substantial additional operating losses for at least the next two years, primarily as a result of expected inc